Q: Why can't the MT9 software detect my Xbus Master using the serial cable?
Xsens Motion Technologies - inertial measurement unit IMU, M...First check if the Xbus Master is turned on (LED flashes). If the LED is solid the Xbus Master may be in Bluetooth mode. Restore to factory defaults to select serial cable mode. Check if the serial cable is correctly attached to the Xbus Master and the host. Use the twist-lock at the Xbus Master side to attach it properly. Make sure that the RS-232 (COM) port used by the Xbus Master is not used by other software installed on your computer, e.g. ActiveSync.
Related QuestionsQ: Why can't the MT9 software detect my Xbus Master using Bluetooth?
Xsens Motion Technologies - inertial measurement unit IMU, M...Q: Why can't the MT9 software detect my Xbus Master using the serial cable? I am using a USB<>RS-232 converter to connect to the host.
Related QuestionsQ: I am using my own serial cable & software. Why can't I read any data?
Xsens Motion Technologies - inertial measurement unit IMU, M...First of all check if the Xbus Master is in serial cable mode. If you use your own cable you must use a null-modem cable with at least five conductors. The following signals must be connected TX, RX, GND, RTS and CTS of which the first two and the last two are crossed! To log data from the Xbus Master the RTS line (host side) must be active.
Related QuestionsQ: Is the Xbus system compatible with the MT9 SDK?
Xsens Motion Technologies - inertial measurement unit IMU, M...Yes, both the MT9 Software and the SDK fully supports the Xbus system, making it easy for you to develop your own application using multiple MT9's with the Xbus system.
Related QuestionsQ: Why does the Xbus Master shut itself off automatically after I turned it on?
Xsens Motion Technologies - inertial measurement unit IMU, M...If the Xbus Master detects no devices (e.g. MT9's) connected on the bus, it automatically turns itself off. Restore the factory default settings (Serial cable mode, 115k2 bps, 100Hz) and use the Xbus Master serial cable to connect to the host.
Related QuestionsQ: What Bluetooth devices does the Xbus Master support (interoperability)?
Xsens Motion Technologies - inertial measurement unit IMU, M...The Xbus Master equipped with a Bluetooth? module has been successfully tested with the following products: Xsens recommends to use one of these products to connect with the Xbus Master Bluetooth for maximum ease of use and performance. These products have been tested with the XM in house. However, most products compliant with Bluetooth v1.
Related QuestionsQ: What is the "Advanced" option in the Xbus Master Settings?
Xsens Motion Technologies - inertial measurement unit IMU, M...If this option is selected the serial port output signals will also be active during Bluetooth connection. NOTE: you can only read from the serial port (log data) and use the sampling moment notification signal. You can not use the serial port to communicate with Xbus Master. If the Advanced option is selected the baudrate will always be 460k8 bps.
Related QuestionsWhy can't the computer detect my external serial mouse?
Welcome : M.B.Solution Private limited : Edge Laptop, Edge S...After you plug in your external serial mouse, you have to go to CONTROL PANEL, run the ADD NEW HARDWARE WIZARD. After doing so, your computer should find your serial mouse and install the Standard Serial Mouse driver for it.
Related QuestionsCan LifeScan exchange a serial cable for a USB cable?
LifeScan United Kingdom -- Technical SupportNo. Although the OneTouch USB cable was more recently introduced, it is not considered an upgrade from the serial cable. Rather, it is a distinct product. The two types of cables are equivalent in quality.
Related QuestionsIs there any software that can help me detect plagiarism?
Plagiarism and Papermill FAQ'sIn addition to online plagiarism detection services there are software programs that can help you determine whether or not a paper, software, or computer program has been plagiarized. Some of the software is free and others cost. A few examples are listed below.
Related QuestionsWhat is the difference between a OneTouch Serial Cable and a OneTouch USB Cable?
LifeScan United Kingdom -- Technical SupportBoth provide equivalent communication for all our meters. The distinction is that each kind of cable is intended for a different kind of connector to the computer. Some newer computers do not provide serial ports, which is why we introduced the USB version of the Interface Cable in 2004.
Related QuestionsQ: What is the latency of the MT9?
Xsens Motion Technologies - inertial measurement unit IMU, M...The duration of the 16 bit AD-conversion (sampling) of the 9 channels of data inside the MT9 takes 1.39 ms. The transmission over the serial RS232 link (@115k2bps) takes 2.17 ms. The total time is 3.56 ms. No, not "officially". However, the DLL COM-object can certainly be used inside the Delphi development environment through the IDispatch interface. No, not "officially". However, the DLL COM-object can certainly be used inside the Java development environment through the IDispatch interface.
Related QuestionsQ: What is the accelerometer range of the MT9?
Xsens Motion Technologies - inertial measurement unit IMU, M...The standard version of the MT9 comes with 2g accelerometers (?20 m/s2 range) but we can deliver a modified version with a 10 g range. This is also possible for the MT6. Please, contact us at info@xsens.com if you need other specifications.
Related QuestionsQ: Is there a USB version of the MT9?
Xsens Motion Technologies - inertial measurement unit IMU, M...No, the MT9 is available in serial output (RS232 or RS485). USB does not support long cables which is not practical in use.
Related QuestionsI can't find my Cakewalk serial number. How do I find out what it is?
Cakewalk - Frequently Asked QuestionsYour serial number is located on your Cakewalk registration card. If you cannot find this card, or if you sent it to us and did not copy the number down, you'll need to call our Customer Service team at 1-888-CAKEWALK (press 2 when prompted). They'll be able to find your number or tell you how to receive a new one. (Back to top)
Related QuestionsI cannot find my serial cable. What should I do?
Qwest.net -- FAQs -- Additional FAQs -- FAQs on Converting t...If you did not receive a serial cable with your Cisco 675 or 678 modem, contact the Qwest Broadband™ support center at 1-800-247-7285.
Related QuestionsI have an HP 1910 Pocket PC. Why can't I find a serial cable?
OBDII ScanTool and SpeedTracer FAQsThe HP 1910 Pocket PC doesn't have a serial cable available for it. Our OBDII connector will not work with this Pocket PC device.
Related QuestionsI did not succeeded to connect my T3 using a serial cable to my GPS ?
Astromist, Palm and Pocket PC Astronomy SoftwareT3 serial port has some bugs. Whatever the configuration software can do, the hardware handshake is always active. As most of ours scopes do not provide such signal, a home made specific connector is mandatory where RTS and CTS pin connected to the T3 serial cable MUST be wired to create a fake signal. This hardware patch will work only for scope. If you are using GPS, there is an other bug in T3 serial management that should cause a crash (buffer overflow).
Related QuestionsQ. What speed should I set for serial RS-232 COM port for cable connection?
Oxygen Software :: Oxygen Phone Manager - PC software for No...Q. I've tried to connect my 2100 with 8210 cable and nothing happens. Your program doesn't detect my phone.
Related QuestionsQ: How do you screw the serial cable onto the iStep platform?
iStep FAQs (Frequently Asked Questions)The iStep platform should have screw anchoring posts (Fig. 2) that you can secure the serial cable to. If your platform does not have these posts, please call or email us. We will get your information and mail you screw anchoring posts to use on your iStep platform.
Related QuestionsQ: What exactly is the difference between the MT6 and MT9?
Xsens Motion Technologies - inertial measurement unit IMU, M...The MT9 includes a 3D magnetometer whereas the MT6 does not. Both the MT9 and the MT6 are inertial measurements units (measuring 3D acceleration and 3D rate of turn (gyro)). The specifications of the MT6 are furthermore equal to the MT9. Our software (Starters Kit and Software Development Kit) does support the MT6, but due to the lack of the earth magnetic field sensors the heading (yaw) cannot be stabilized from rate gyro drift.
Related QuestionsQ: Can I use the MT9 SDK with my PocketPC?
Xsens Motion Technologies - inertial measurement unit IMU, M...We currently have a beta-release of the MT9 SDK for the PocketPC platform. Please, contact support@xsens.com if you are interested.
Related QuestionsQ: What is the rate gyro range of the MT9?
Xsens Motion Technologies - inertial measurement unit IMU, M...The standard version of the MT9 comes with 900 deg/s rate gyros (?900 deg/s range) but we can deliver a modified versions with 150 deg/s and 300 deg/s. This is also possible for the MT6. Please, contact us at info@xsens.com if you need other specifications.
Related QuestionsQ: Is it possible to connect the MT9 to a PocketPC?
Xsens Motion Technologies - inertial measurement unit IMU, M...Yes, all PocketPC's (we currently know of) support standard RS232 input (mostly with supplied RS232 synch cable) so you can develop software for the PocketPC using binary data from the MT9 or log the inertial data on the PocketPC (please contact us if you would like to receive a simple binary datalogger for the PocketPC).
Related QuestionsQ. What is a Master Promissory Note?
Finalcial Aid FAQ - Frequently Asked QuestionsThe MPN is a multi-year note, which allows the borrower to complete the note once and borrow in subsequent years with out completing an additional note.
Related QuestionsWhy can't I detect my device using ActiveSync on my PC?
FAQ - JASJAMSome personal firewalls may prevent Activesync from detecting your device, especially when using high security configurations. If that does not work, please check that the correct version, 4.1 or higher, of Microsoft Activesync is installed on your PC/laptop and that USB or Bluetooth connections are enabled (ActiveSync > File > Connection Settings > "Allow USB Connections" or "Allow Connections to one of the following COM").
Related QuestionsWhy can't I run my RT/2127 software and connect to my serial port?
FAQThe RT/2127 software can not share the serial port with other active software. For example, if you have a PDA cradle normally connected to COM1: and the PDA software is active on COM1: you will receive an error from our software when attempting to use the port.
Related Questions