Can I power the two power supplies of the Cisco 7500 Series Router from two different feeds?
Cisco - Cisco 7500 Series: Frequently Asked QuestionsYes, you can power the two power supplies from different feeds. However, be aware of potential differences in the grounds; take this consideration very seriously. Connect the neutral-to-ground bond of the generator to the neutral-to-ground bond of the utility service entrance to eliminate any potential differences or, at least, bring them down to acceptably low levels. Caution: Cisco does not recommend hardware products for use on floating feeds.
Related QuestionsWhat are the minimum circuit breaker requirements for a Cisco 7500 Series Router DC power supply?
Cisco - Cisco 7500 Series: Frequently Asked QuestionsSize the breaker for the Cisco 7513 Series Router to deliver 40 A (amperes) to the system. The breaker for the Cisco 7507 Series Router must provide 24 A. You must respect local codes when you size breakers, but as a general rule of thumb you must have 25 percent extra current capacity. Therefore: These sizes are based on the minimum input voltage of -40.5 Volts of Direct Current (VDC). Each of these systems has redundant power supplies as an option.
Related QuestionsHow can I find the serial number of my Cisco 7500 Series Routers chassis?
Cisco - Cisco 7500 Series: Frequently Asked QuestionsThe show rsp chassis command was introduced in Cisco IOS® Software releases 12.0(13)S and 12.0(13)SC. Router>show rsp chassis-info Backplane NVRAM(ver 1) contents: Chassis model: 0x01 Chassis S/N: 50014400 MAC base: 0060.5C51.1A00 MAC block size: 1024 RMA failure: 0 RMA number: 0 Manufactured Date: 96 12 10 Router>
Related QuestionsWhat is the fan transfer point in a Cisco 7513 Series Router?
Cisco - Cisco 7500 Series: Frequently Asked QuestionsThe Route/Switch Processor (RSP) is able to adjust the speed of the blower on the Cisco 7513 Series Router, based on the detected temperature. The fan transfer point is an indication of the RSP correction on the fan speed (1 percent represents minimum speed, and 100 percent represents full speed).
Related QuestionsWhy does my Cisco 7507 Series Router report "PS1 Output is 0 W"?
Cisco - Cisco 7500 Series: Frequently Asked QuestionsThe Cisco 7507 Series Router does not report the current consumption (measured in amperes) used, and therefore cannot compute the power (watts). The Cisco 7507 Series Router does report the individual bus voltage, but that is all. The Cisco 7513 Series Router reports the current consumption and, therefore, can also report the power.
Related QuestionsCan a cisco router be a ''true'' firewall?
This depends on the definition of firewall. Some writers (e.g., Gene Spafford in _Practical UNIX Security_) define a firewall as a host on which an ''inside'' and/or an ''outside'' application process run, with application-level code linking the two. For example, a firewall might provide FTP access to the outside world, but it would not also provide direct FTP service to the inside world.
Related QuestionsWhat is the different between ACE-540A and RP1072-24 power supplies?
ipc2U - Industrial PC to youThis page was printed from IPC2U site - Industrial computers catalog (http://www.ipc2u.com) on 05.09.2007.
Related QuestionsHow do I perform load sharing of power supply (PS1 and PS2) in Cisco 7513 Series Routers?
Cisco - Cisco 7500 Series: Frequently Asked QuestionsYou can divide load sharing of power 40%/60% or better on the +5V and +12V. This value can vary from 50% to 100% based on the load between any two power supplies PS1 and PS2. PS1 + 5V Current measured at 51.76A (capacity 200 A) PS1 + 12V Current measured at 1.92 A (capacity 35 A) PS1 - 12V Current measured at 0.04 A (capacity at 3 A) PS1 output is 285 W PS2 + 5V Current measured at 60.39 A (capacity 200 A) PS2 + 12V Current measured at 2.61 A (capacity 35 A) PS2 - 12 V Current measured at 0.
Related QuestionsHow much memory is installed in my Cisco router?
Cisco - Cisco 1700/2600/3600 ADSL WIC Frequently Asked Quest...Issue the show version command and press Enter. The amount of memory installed is displayed, as shown in these examples. 1720>show version cisco 1720 (MPC860) processor (revision 0x601) with 36864K/12288K bytes of memory. 16384K bytes of processor board System flash (Read/Write) 2600>show version cisco 2620 (MPC860) processor (revision 0x200) with 59392K/6144K bytes of memory. 32K bytes of non-volatile configuration memory.
Related QuestionsI don't have a Cisco router. Should I?
North Atlantic Networks (support/faq)Yes. North Atlantic Networks strongly believes in Cisco and recommends their products. While other routers may provide excellent services, our belief is that going with the industry leader solves many problems before they ever occur. Cisco's products are incredibly reliable and backed by a very strong support department. And, because North Atlantic Networks is a Cisco Premier Certified Partner, we are able to service your router immediately should you have any problems.
Related QuestionsHow do I setup NBAR on my Cisco router?
Somix - Main MenuMake sure you enable NBAR on the router for the interfaces you want to collect statistics on. Call us if you need help setting it up. You must first enable Cisco Express Forwarding (CEF) on the router before enabling NBAR. Interfacing with NBAR on your Cisco router is done through the Modular QoS Command-Line Interface (Modular QoS CLI).
Related QuestionsDo your fiber bundles fit power supplies from different manufacturers?
Navitar Machine Vision - Solutions - Research/Learn - FAQ'sNavitar fiber bundles typically fit into power supplies with 0.5” or 0.72” diameter fiber receptacles. Custom couplers can be designed to fit other power supplies.
Related Questionsgt;What level of software is required for NTP support in >a cisco router?
It is a software feature exclusively. Anything that supports 9.21 or 10 will run NTP (when running that s/w).
Related QuestionsWhich switch type should I select on my Cisco router?
B-LinkU ISDN Simulator FAQsThe B-LinkU defaults to using the ETSI Euro-ISDN protocol (basic- net3). If you would like to use SPIDS, change the switch type to US NI 1 in the Unit tab, and select support for basic - NI on your router. Yes. The B-LinkU allows the user to enter one SPID value for both ports or one SPID value for each port. Although several SPID values may be entered in this way, the B-LinkU only supports one service profile which allows any type of terminal to respond to any type of call.
Related QuestionsQuestion: Is there an upgrade available for the Power Macintosh 7200 series computers?
Power Macintosh 7200 Series: Frequently Asked QuestionsAnswer: The Power Macintosh 7200 series computers can currently be upgraded to a Power Macintosh 7600/120. See the following Tech Info Library article for more detailed information, or contact your local Apple-authorized service provider:
Related QuestionsHow is it different from all the RSS feeds available elsewhere?
welcome to the roosster's homeThe Roosster focusses on making information NOT available via RSS anywhere on the web, available through this wonderful format. The Roosster converts information available on the web in formats other than RSS - like HTML - into RSS for easy reading in a desktop RSS reader. It also allows you to create your own custom feeds based on keywords across ALL gathered feeds. Further, the Roosster also FINDS deals that are otherwise harder to find by scouring the web for the latest deals.
Related QuestionsAre power supplies dangerous?
Project FAQAbsolutely. You will be exposed to AC line power wires while building it, and the filter capacitors store a lot of energy. You must exercise due caution while building it to avoid electrocution. Wall power can kill! This is a do-it-yourself project. That means that all benefits are yours, and all of the responsibility is yours.
Related QuestionsAre the power supplies hot-swappable?
ProCurve Networking by HP - Support - Häufig gestellte ...Yes, the 9408sl power supplies are hot-swappable. However, the power cord must be disconnected before the power supply is removed from or installed into the chassis.
Related QuestionsWhat kind of power supplies are used with the system?
Aviom FAQsAviom Personal Mixer products use external DC power supplies. External supplies are used to help make products quieter and less expensive. By adding the A-16D or A-16D Pro A-Net Distributor, the need for the DC power supply for each Personal Mixer connected to it can be eliminated. The A-16D Pro Distributor has eight built-in isolated power supplies that can power eight Personal Mixers directly.
Related QuestionsWhat is the warranty period on your Power Supplies?
Innovative Energies - SUPPORT FAQInnovative Energies manufactured and most imported products have a 2 year warranty period from date of purchase unless otherwise stated.
Related QuestionsWhat power supplies are required for the Paracube®?
Paracube® Paramagnetic Oxygen Transducer - FAQThe Paracube® and the electrochemical sensor are diffusion devices of comparable size. Both sensors can therefore take advantage of the same, simple sampling system.
Related QuestionsWhat about uninterruptible power supplies (UPS)?
Open Voting Frequently Asked Questions | Open Voting Consort...The OVC believes that all electronic voting equipment, with the possible exception of high-current draw machines such as laser printers, should be protected by uninterruptible power supplies. Low cost uninterruptible power supplies will only be able to cover power outages of short duration, typically an hour or less. Good uninterruptible power supplies have means to indicate how much time is left before they go dark.
Related QuestionsWhat are switch mode power supplies?
These are the kind of power supply used in almost every type of system designed and sold today. They replace earlier generation linear power supplies which were larger, less efficient, and more expensive. Switch mode power supply technology is one reason modern equipment is smaller, cooler operating and more economical.
Related QuestionsDo power supplies come with your cases?
Logic Supply - Frequently Asked QuestionsIn general, power supplies do come with our cases and barebone systems. Check the Case Matrix to confirm that the case includes a power supply. Also, each case lists on its product page the power requirements and which power supply comes in a standard unit. Most of our standard power supplies are laptop-style PSU’s with an external AC-DC brick and an in-case DC-DC converter.
Related QuestionsWhy is it that my Cisco 800 router does not run OSPF?
Cisco - OSPF: Frequently Asked QuestionsCisco 800 routers do not support OSPF. However, they do support Routing Information Protocol (RIP) and Enhanced Interior Gateway Routing Protocol (EIGRP). You can use the Software Advisor ( registered customers only) tool for more information on feature support.
Related QuestionsCan you give an example of a simple CIDR configuration for a cisco router?
www.de.buehler.net : CIDR-FAQ 2000 : Wilhelm BühlerThe following example creates 2 aggregates and suppresses any more specific addresses that may be contained within those aggregates. The access-list causes only those nets to be distributed as listed, and not any others that may exist in the BGP routing tables. router bgp 64100 no synchronization aggregate-address 172.16.0.0 255.248.0.0 summary-only aggregate-address 192.168.50.0 255.255.255.0 summary-only neighbor 192.168.54.2 remote-as 65000 neighbor 192.168.54.
Related QuestionsWhat causes problems when you enable compression between a Cisco and an Ascend router?
Cisco - WAN Compression FAQsIt is a problem with the default configuration on the Ascend box. Contact your Lucent Technologies Technical Support Representative. This is known problem Cisco bug ID CSCdk39968 ( registered customers only) . The solution is to upgrade to Cisco IOS Software Release 11.3(7) or later code.
Related QuestionsHow do I recover a password on the Cisco 1700, 2600, or 3600 router?
Cisco - Cisco 1700/2600/3600 ADSL WIC Frequently Asked Quest...For information on this topic, refer to Password Recovery Procedure for the Cisco 1700 Series Routers. You can use this procedure for the Cisco 1700, 2600, and 3600 series router.
Related QuestionsHow can I play games through my DSL router (Cisco 675) when I have NAT enabled?
XMission : Support : Miscellaneous : FAQsMany customers have found out that the Network Address Translation (NAT) functions of the Cisco 675 External DSL Router interfere with interactive internet games. Cisco has overcome this problem with the release of the v2.2.0 CBOS operating system. You can download this update from ftp.xmission.com (using your XMission username/password), and then going to /archive/dsl.
Related Questions