Search 5,000,000+ questions and answers.

Frequently Asked Questions

How often should I calibrate my instrument?

Instrument troubleshooting--Frequently asked questions
What is considered "normal" sensor weight loss? [Applicable to LD, RM, and PLC Series continuous monitoring systems, and portable sensors for formaldehyde and hydrazine]
Related Questions

Can I calibrate a module myself?

Synthesizers.com --- FAQ - Frequently Asked Questions
Sure, every module that requires calibration comes with calibration instructions. Usually this takes a good frequency counter, volt meter (4+ digits), oscilloscope, and a precise voltage source (+/-1mv). All modules are calibrated before shipping with very accurate test equipment so you don't have to worry about this, but many people like to know what all of those trim-pots are for on the PCB. Many modules require no calibration at all.
Related Questions

How often do I have to calibrate?

Frequently Asked Questions
Calibrating Vulcan On-Board Scales is a simple process. Once initially calibrated, you may never have to calibrate again.
Related Questions

Gas detection instruments are potential life-saving devices. Recognizing this fact, Industrial Scientific Corporation recommends that a functional ("bump") test be performed on every instrument prior to each day's use. A functional test is defined as a brief exposure of the monitor to a known concentration of gas(es) for the purpose of verifying sensor and alarm operation and is not intended to be a measure of the accuracy of the instrument.
Related Questions

Why do I have to calibrate?

Frequently Asked Questions About the MiniMed ParadigmŪ REAL-...
Calibration is like buying a watch and setting the time for the first time. Glucose sensors are similar in nature. To initialize a glucose sensor, you need to enter a meter reading to give the system a starting point. And, just as a watch needs to be adjusted occasionally, so does a glucose sensor. You need to enter at least two meter readings a day – once every 12 hours.
Related Questions

Medtronic Diabetes - Paradigm REAL-Time: FAQ
Calibration is like buying a watch and setting the time for the first time. Glucose sensors are similar in nature. To initialise a glucose sensor, you need to enter a meter reading to give the system a starting point. And, just as a watch needs to be adjusted occasionally, so does a glucose sensor. You need to enter at least two meter readings a day – once every 12 hours.
Related Questions

How can I calibrate the speed and/or incline of my machine?

ProForm Customer Service: Frequently Asked Questions : Tread...
To calibrate the speed and/or incline, please refer to the instructions that are under the motor hood cover or are mounted on the inside of the belly pan. Be sure to unplug your machine. If the instructions are not there, please contact our customer service department at 1-888-533-1333 while you are near your machine. Make sure the heart rate monitor is under your clothing, against your skin, and as high under the pectoral muscles as is comfortable.
Related Questions

Can I calibrate the logger myself? How often should it be calibrated?

Marathon Products Frequently Asked Questions
No, you can not calibrate the logger yourself. It must be returned to Marathon for calibration. However, some of our larger customers who have metrology laboratories check the logger's calibration against a reference standard in lieu of returning it to Marathon. This depends on your Quality Control procedures. Some companies write into their Standard Operating Procedures that all measuring and controlling instruments must be checked for calibration every 6 or 12 months.
Related Questions

How do I calibrate my dial thermometer?

Victory Refrigeration: Services: FAQ
Check the cabinet temperature by using an accurate hand-held dial or digital thermometer placed next to the thermometer sensing bulb (located in the upper right hand corner of the cabinet). If the dial thermometer on the cabinet grill matches the test thermometer (+/-10F), do not adjust. If temperatures do not match (+/-10F), remove the dial thermometer lens with a small screwdriver. To adjust the temperature needle, insert a small screwdriver in the slotted screw on the needle.
Related Questions

How do I calibrate my analog hygrometer?

Cigar FAQ
It always helps to know which end is which and what everything is called. The majority of cigars come with one open end (the foot) which is the end that you will light. The other end (the head) is the end that you must cut, and through which you will draw air and delicious smoke. To make life easier, the band is most often placed near the head.
Related Questions

How does Sierra calibrate mass flow meters?

Flow meter, mass flow controller, mass flow meter, flowmeter...
Every single 800 Series Sierra Flow meter is calibrated on a Primary Standard. Sierra does NOT use transfer standards. We can not stress how beneficial this is to YOU as the end user! The reason nobody else calibrates EVERY meter on a Primary Standards because the cost to calibrate Flow Meters with Primary Standards is IMMENSE however it is TRULY the ONLY way any company manufacturing Mass Flow Meters with accuracies of 1% or better could justifiably make such claims of accuracy.
Related Questions

How do I calibrate the scale?

FAQ - PSC / Percon - Magellan SL
Scale calibration procedures and illustrations are available in Section 5: Calibration Procedures in the installation and operation manual. Note: Calibration must be certified by Weights & Measures in your state.
Related Questions

Can I calibrate VibroMatrix?

VibroMatrix - FAQ
Yes. The system includes a calibration function which allows to calibrate the entire measuring chain from the sensor to the display in one step using a vibration calibrator.
Related Questions

How often should I calibrate the Millennium/GS2?

Net Safety Monitoring | Sales Department | FAQ and Industry ...
Net Safety recommends that the Millennium (and every sensor for that matter) is calibrated every three months. However, depending on the environment in which the sensor is installed, more frequent calibration may be required.
Related Questions

How do I calibrate my joystick?

Dave Brown Products - Support: RCFS2001 FAQ's
The calibration process changed in version 1.1.01 of RCFS 2001. In this version, the calibration process is handled within the RCFS 2001 program. From the main RCFS 2001 windos, click the button titled "Calibrate Joystick..." IMPORTANT: You must add SimStar to the Gaming Options in the Windows Control Panel and its status must be "OK" before you can calibrate. Center both sticks in both the x and y axes. Click "Calibrate.
Related Questions

How do I calibrate to your printer?

Fine Art Canvas Printing and Reproduction, Giclee Printing, ...
You don't calibrate directly to our printer. You calibrate your monitor to a standard and neutral state. We recommend all clients perform hardware monitor calibration. This is a relatively straightforward and simple procedure. We recommend Colorvision Spyder 2 Pro or Gretag MacBeth Eye One Display 2. We also offer colour consultancy services.
Related Questions

How do I calibrate the MicroCell?

Conception Technologies: FAQs
Follow the directions in the users manual. Using the stage micrometer included in the starter kit, measure the distance across all 10 boxes of the reticle. Divide this number by 10. That is D. This factor is unique for each scope and magnification. Every time you change magnification a new factor must be calculated.
Related Questions

how can i calibrate my humidor?

Cigar, Cuban Cigars, Cigar Accessories
I'm a confirmed cigar smoker, and I would like to know if there is an easy way to quickly remove the odor from my moustache after smoking a cigar. I'm certain it's mostly nicotine odor. I've tried toothpaste, but it doesn't begin to affect it. I got my cigars through a mail order, and they all came with cello wraps on them. I put them in my humidor (67 degrees, 70% RH controlled) with the wraps left on.
Related Questions

How do I calibrate my analyzer?

Continental Hydrodyne Systems, Inc. - Frequently Asked Quest...
Both the AquaKing® and EZ-check use our Patented Curve fit (CF™) Technology which doesn't require any factory or end user calibration. The units self-calibrate every time a sample is analyzed.
Related Questions

How do I calibrate my monitor?

FAQs
E-mail us and ask for a calibration file and printed postcard. You will need Photoshop to calibrate your monitor properly.
Related Questions

How do I calibrate the VHS-1?

Haze-SPAN: Instrument FAQ
When you use the LANGLEY METHOD to determine the EXTRATERRESTRIAL CONSTANT for your instrument, you are calibrating your instrument.
Related Questions

back to top] How often should I calibrate the VHS-1?

Haze-SPAN: Instrument FAQ
It's wise to use the LANGLEY METHOD to CALIBRATE the VHS-1 at least once each year. Ideally, you should try to use the Langley method on 3 very clear days.
Related Questions

Got A Question? Ask Our Community!


More Questions >>

© Copyright 2007-2008 QueryCAT
About • Webmasters • Contact